U355B
Charge Air Cooler Outlet Pressure Sensor 2 Circuit
U355B points to a circuit problem with pressure sensor 2 at the charge air cooler outlet. J2012 lists two at this spot, which points to a pair used for cross-checking; how a maker splits the roles is unpublished, and no public document uses U355B. A GM patent shows the principle: before start-up, while the compressor stands still and the cathode holds only atmospheric pressure, readings are compared, and a doubtful sensor is replaced by a value calculated from the remaining ones. Ford names a winter risk on the wet air side: water on a sensor diaphragm can freeze and give no or false output at a cold start, which may lead to a shutdown. Sensor 1 at the same spot is U355A. With only one valid sensor left, output may be limited.
Possible causes
- Open, short or corrosion in wiring or connector of sensor 2 high
- Condensed water frozen on the sensor (occurs at cold start, may clear when warm) medium
- Pressure sensor 2 faulty internally medium
Symptoms
- Fuel cell system warning, MIL on
- Start refused or system shuts down shortly after a cold start
- Reduced power while only one pressure sensor is valid
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for U355B
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.