U3554
Hydrogen Tank B Valve Enable Circuit
U3554 refers to the enable path that powers the tank B solenoid. Its purpose is a second, independent way to withdraw the permission for the valve to open. Toyota patented a layout in which the valve controller and the controller for high voltage sit at opposite ends of the car and back each other up: after a crash at one end, the controller at the undamaged end shuts the hydrogen valve. Toyota's FCHV guide also lists an opened hood or fuel door among the triggers that close the valves. A fault in such a release path keeps tank B shut even with an intact coil. No maker documents U3554 publicly. Check fuses, relays and the release wiring before the valve itself; U3553 covers the control side of the same valve.
Possible causes
- Enable relay or switch in the supply path faulty medium
- Open or short in the enable line to valve B medium
- Faulty input that withdraws the release, such as a crash or flap signal low
Symptoms
- Hydrogen system warning
- Range reduced or no READY
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for U3554
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.