U3551
Hydrogen Tank A Valve Enable Circuit
U3551 concerns the enable circuit of the valve on tank A: not the switched control line, but the path that permits the valve to be powered at all, typically a relay, fuse or supply-side switch. Designs keep it apart so a crash can cut hydrogen reliably. In a Honda patent the fuel cell controller opens a collision cutoff relay as soon as the airbag unit reports an impact, and FMVSS 307 demands valve closure no later than 5 seconds after a crash. Toyota's FCHV guide follows the same idea: pulling two fuses disables the vehicle and closes every tank valve. If this path is open or shorted, tank A cannot open. No manufacturer documents U3551. Enable codes on several tanks at once point to a shared supply.
Possible causes
- Enable or crash cutoff relay faulty medium
- Blown fuse or missing supply in the valve enable path medium
- Open or short in the enable wiring to valve A medium
Symptoms
- No READY or fuel cell does not start
- Hydrogen system warning
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for U3551
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.