U3547
High Voltage System Interlock Circuit P Low
U3547 reports a low value on loop P, and the contactors drop out with it. A design flaw can be the cause too. Kenworth (campaign 25KWC) and Peterbilt (25PBC) recalled battery electric T680E, 520EV and 579EV trucks under NHTSA number 25V181: with certain HVIL circuit layouts in their Accelera power control accessory subsystem, high voltage could be lost and the contactors open without warning, cutting propulsion. The remedy pairs a software check with two overlay harnesses. If a commercial vehicle keeps losing power on loop P, ask for open campaigns before hunting for wiring faults. No maker documents U3547.
Possible causes
- Interlock circuit layout covered by a recall, overlay harness not yet fitted medium
- Plug in loop P open or interlock pin pushed back medium
- Loop P wire shorted to ground medium
Symptoms
- Sudden loss of propulsion while driving
- Contactors open without prior warning
- No restart until the loop reads normal
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for U3547
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.