U3545
High Voltage System Interlock Circuit P
U3545 is the general fault code for interlock circuit P, the fifteenth loop. Interlock electronics can be harmed by events elsewhere in the drive. Allison service letter SIL 3-EP-14 (Rev. C, 2017) for the H 40/50 EP hybrid system used in buses offers a separate HVIL circuit card for the DPIM2 inverter: if the check list shows 3 to 4 µF between DC+ or DC− and chassis, for example after an internal stator short, that card is damaged and can be swapped instead of the whole inverter, which first has to come out of the vehicle; an ESD wrist strap is mandatory. No maker documents U3545.
Possible causes
- Interlock circuit board inside the inverter damaged, e.g. after a motor winding short medium
- Connector in loop P not fully latched medium
- Loop P wiring damaged medium
- Electrostatic damage to monitoring electronics during service low
Symptoms
- Vehicle cannot be made ready
- Other drive faults stored at the same time, such as motor or isolation faults
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for U3545
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.