U353B
High Voltage System Interlock Circuit M Low
U353B is set when loop M reads too low. A lever-type plug can leave it in exactly that state on purpose. A connector patent by Hyundai and Kia adds an intermediate lock to the lever: on the way out it stops at a point where the interlock contacts are already apart while the power terminals still touch, so the system has time to switch off before the second lever movement separates the plug. If such a plug is left at the intermediate stage after service, or not pushed fully home, loop M stays open although the plug seems attached. Check every lever on the loop for its final locked position. No maker documents U353B; the contactors remain open.
Possible causes
- Lever-type connector in loop M left at its intermediate position high
- Loop M wire shorted to ground medium
- Loop M source in the controller failed low
Symptoms
- No ready mode after service on high-voltage plugs
- Fault persists after clearing
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for U353B
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.