U3538
High Voltage System Interlock Circuit L High
U3538 is stored when loop L overshoots its permitted maximum. In a constant-current loop that can be a contact problem rather than foreign voltage. Tesla's Model S tech note records its most frequent HVIL field failure as high-voltage plugs serving the cabin PTC heater, the heater for battery coolant and the A/C compressor harness whose interlock pins were too short: the supplier had changed the housing without lengthening the pins, and in the worst case male and female never met. Higher resistance raised the loop voltage until the fault set. Replacement plugs with longer pins carry a yellow dot. Comparable part revisions can matter on any loop L. No maker documents U3538; high voltage stays off.
Possible causes
- Connector revision in loop L with interlock pins too short for reliable contact medium
- Loop L wire in contact with a 12 V supply medium
- Spread female terminal in a loop L connector medium
Symptoms
- Vehicle does not become ready or switches off high voltage
- Heating or air conditioning affected if their plugs are part of the loop
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for U3538
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.