U3534
High Voltage System Interlock Circuit K High
U3534 reports loop K above its upper threshold. Besides a loop wire chafed onto a 12 V feed, the timing of the electronics can be behind it. In the Texas Instruments reference design TIDA-020069 a 10 mA constant current feeds the loop, and that source can be disabled to save power or to hold the loop in a deliberate fault state until the other systems are ready. Its current then shrinks to one hundredth, and send and return voltages look like a short to battery. If software reads loop K before enabling the source, or the enable line hangs, a high result appears although the wiring is sound. No maker documents U3534. Rule out foreign voltage first, then ask about controller software updates.
Possible causes
- Loop K wire in contact with a 12 V supply high
- Loop source still disabled when the controller evaluates loop K medium
- Controller software with faulty start-up sequence low
Symptoms
- Vehicle does not become ready
- Fault may appear right at switch-on although no wiring damage is found
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for U3534
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.