High Voltage System Interlock Circuit K Low
U3533 says loop K reads too low. Apart from an open plug, part of the loop current may be escaping somewhere. Tesla's HVIL tech note for the Model S describes two such cases: a drive inverter whose control board leaked some of the nominal 20 mA loop current to ground, and a loop wire squeezed against ground close to a seat belt pretensioner. The fault therefore need not sit in a connector at all; a component on the loop or a wire trapped by seat or trim parts can cause it. When every plug of loop K is latched and the value stays low, measure the loop current at each component and inspect wiring near seat mounts. No maker documents U3533; the contactors remain open.
Possible causes
- Loop K wire squeezed against ground by seat, trim or mounting parts high
- Plug within loop K not connected medium
- High-voltage component on loop K leaking loop current to ground internally low
Symptoms
- Vehicle does not reach ready mode
- Fault may follow work on seats or interior trim
- Warning to have the high-voltage system checked
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for U3533
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?