U352F
High Voltage System Interlock Circuit J Low
U352F means loop J reads below its lower threshold, the picture an interrupted loop gives. In high-voltage plugs the interlock pins are shorter than the power pins, so they part first when the plug is withdrawn. A TE Connectivity product manager puts the resulting lead at just one to three milliseconds for a plug pulled quickly, while switching the whole system off can take close to a second, and adds that a closed loop does not prove full mating. A Hyundai and Kia connector patent names the same weakness of fast separation. A plug in loop J that has been pulled back slightly, or a dropped interlock pin, is thus the first suspect. No maker lists U352F; the contactors stay open.
Possible causes
- High-voltage plug in loop J partly withdrawn, interlock pins already apart high
- Interlock pin in loop J pushed back in its cavity medium
- Loop J wire chafed through to ground medium
Symptoms
- High-voltage system switches off and stays off
- No ready mode after work near high-voltage plugs
- Charging not possible
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for U352F
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.