U352B
High Voltage System Interlock Circuit H Low
U352B reports too low a level on interlock loop H. Apart from a pulled plug or a grounded wire, a deliberate opening can cause it: Texas Instruments mentions feeding a crash signal into the loop so that high voltage shuts off after an accident. The DGUV warns that such a crash shutdown does not establish absence of voltage and that disconnection following the maker's rescue sheet is still advisable; FMVSS 305a takes its post-crash voltage readings in a window from 10 s to one minute after the impact. No maker documents U352B. After a collision, replace damaged loop sections rather than patching them, and have trained staff isolate the system.
Possible causes
- Loop H opened on purpose by a crash signal after an accident medium
- Loop H wiring or plug damaged in a collision medium
- Loop H wire shorted to ground medium
Symptoms
- High voltage off after an accident or airbag deployment
- Vehicle cannot be made ready
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for U352B
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.