U352A
High Voltage System Interlock Circuit H Performance
U352A says the eighth loop is closed but its electrical values leave the calibrated band. In CATL's interlock patent the decision thresholds follow from the loop current, a sensing resistor and the impedance of every HV part in the chain. A long loop through many parts therefore has narrow margins: each extra contact, a replacement part with different internal resistance or a lengthened harness shifts the result. That makes a performance fault on a late loop plausible after repairs or conversions. No maker publishes U352A. Compare part numbers of recently fitted HV parts with the originals and look for added plugs in loop H.
Possible causes
- Replacement HV component with different interlock resistance fitted medium
- Extra connector or harness extension added to loop H medium
- Rising contact resistance at several loop H terminals medium
Symptoms
- Fault appears after a repair or conversion
- High-voltage system switches off occasionally
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for U352A
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.