U3527
High Voltage System Interlock Circuit G Low
U3527 sets when the level on loop G drops below what the module expects. When several controllers watch interlock lines, the reporting unit already narrows the search. A Mercedes service bulletin on the 243 model series shows this with loop A codes: the DC charging unit and the AC charger each store a ground-short code, the battery management a short to positive, and the PTC heater has a separate code. For loop G, start measuring at the controller storing U3527, follow its section outward and compare the codes in the other units. No maker publishes U3527. While the low reading persists, the contactors behind loop G stay locked.
Possible causes
- Loop G wire cut or chafed to ground near a control unit high
- Plug in the section of the reporting unit not connected medium
- Loop source of the reporting controller failed low
Symptoms
- Vehicle does not become ready, or charging is refused
- Interlock codes in more than one control unit
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for U3527
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.