U3526
High Voltage System Interlock Circuit G Performance
U3526 reports an implausible result for loop G. Not every interlock is a wire loop: Rivian patented a virtual interlock in which a controller first brings the DC bus up to a low, safe voltage only, gathers the voltages that the high-voltage components report over CAN, and raises the bus to operating voltage only if those reports are acceptable. With such a scheme a performance fault means values that contradict each other rather than a broken wire, for example one component seeing a bus voltage far from the battery's. No maker documents U3526. Missing or stale CAN data, a faulty voltage sensor or a loose HV plug are the main suspects.
Possible causes
- Voltage sensing inside one high-voltage component faulty medium
- Voltage message missing or late on the CAN bus medium
- HV plug not fully seated, so one component sees no bus voltage medium
Symptoms
- Start-up of the high-voltage system aborted
- Communication codes in other control units at the same time
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended