U3523
High Voltage System Interlock Circuit F Low
U3523 is logged when loop F reads too low, typically from an open plug or a wire shorted to ground. Tracing it means working close to high-voltage parts. The German statutory accident insurance DGUV lets only trained high-voltage staff de-energise the system and insists on the order: isolate, secure against switching back on, then prove absence of voltage with a suitable tester, not a multimeter. Only then open loop F plugs, measure sections or bridge the loop for a test; a bridge must never stay in place, as it defeats the protection. No maker documents U3523. The vehicle stays without high voltage until the cause is fixed.
Possible causes
- Plug in loop F open or not engaged after service high
- Loop F wire shorted to ground medium
- Broken interlock connector housing or locking tab medium
Symptoms
- Vehicle not ready to drive, high-voltage warning shown
- Charging not possible
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for U3523
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.