U3521
High Voltage System Interlock Circuit F
U3521 flags an unspecified fault in loop F, the sixth interlock loop. Extra loops often guard service openings rather than cables. FMVSS 305a defines the service disconnect as the device that switches the circuit off for checks and service and demands finger protection wherever it opens without tools; its interlock tells the controller when it is pulled. Covers can be watched without contacts too: GM patented an interlock switch built from a magnet and a reed relay that stays closed only while the magnet is near. No maker publishes which opening belongs to loop F. Check that the service plug is fully locked and that magnet covers sit correctly.
Possible causes
- Service disconnect not fully inserted or its lever not locked high
- Cover with interlock magnet missing, swapped or mounted out of position medium
- Reed relay or switch contact of the cover interlock failed low
- Loop F wiring damaged low
Symptoms
- No ready mode after battery or service work
- High-voltage system message in the cluster
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for U3521
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?