U3520
High Voltage System Interlock Circuit E High
U3520 means the fifth interlock loop sits above its permitted range, usually because a loop wire has picked up battery voltage or another low-voltage feed. Lear's patent for a pulsed interlock tester shows how to pin this down further: it measures current at generator and detector pins and, by comparing them, works out at which end the unwanted link to the 12 V side lies. Simpler controllers only see the raised level. No manufacturer has published U3520. In the workshop, test each loop E wire against 12 V with the plugs at both ends disconnected; wet or corroded connectors next to fused feeds are typical spots.
Possible causes
- Loop E wire shorted to a 12 V supply high
- Water or corrosion bridging a loop pin to a supply pin medium
- Loop source in the controller stuck on low
Symptoms
- No ready mode, high-voltage warning shown
- Fault reappears directly after clearing
Inspection / repair
- Difficulty: hard
- DIY: shop recommended