U351F
High Voltage System Interlock Circuit E Low
U351F reports a low reading on interlock loop E, the usual result when a plug in that loop is separated or one of its wires is grounded. The US standard FMVSS 305a explains the hurry: a high-voltage connector that can be pulled without tools may, as one permitted option, bring its live parts to 60 V DC or less within one second of separation. The interlock gives the early signal for that; Texas Instruments describes the follow-up of stopping traction, opening the power relays and discharging the DC-link capacitors. No maker documents U351F. Expect abrupt loss of drive power and no restart until loop E reads normal.
Possible causes
- High-voltage plug with interlock in loop E pulled or backed out high
- Loop E wire chafed through to ground medium
- Interlock pin pushed back in its housing medium
Symptoms
- Abrupt loss of drive power, often with a stop-safely message
- Vehicle cannot be restarted in ready mode
- Charging aborted or impossible
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for U351F
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.