U351D
High Voltage System Interlock Circuit E
U351D covers a disturbed fifth interlock loop, circuit E, where the module cannot narrow the fault down. Five loops arise naturally if every protected housing gets its own circuit. A GM patent describes this: each high-voltage enclosure has a functional interlock tied to its access point, and the low-voltage signal inside only gets through while that opening is closed. Removing a cover is thus noticed by the circuit of that very housing. Which enclosure belongs to loop E is not published. Check covers, lids and their screws first, then the plugs of the housings involved; high voltage stays off until loop E is closed.
Possible causes
- Cover of a high-voltage housing on loop E not fitted or not fully tightened high
- Interlock contact or bridge in the cover bent or broken medium
- Loop E wiring damaged between housings medium
- Evaluating controller faulty low
Symptoms
- No ready mode after work on a high-voltage component
- High-voltage warning in the instrument cluster
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for U351D
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.