U351A
High Voltage System Interlock Circuit D Performance
U351A says that loop D returns a signal, but not the one the module sent out. Many designs feed the loop with pulses rather than a steady level. In a Corun battery patent a microcontroller sends a 0 to 5 V square wave at 100 Hz with half on, half off through the interlock switches of pack, motor controller and vehicle controller, and treats the loop as sound only if frequency, on-time and amplitude return unchanged. A rounded, shifted or weakened pattern hints at contact resistance, moisture or coupled interference rather than a clean break. No maker documents U351A. High voltage may drop out without warning.
Possible causes
- Corroded or worn interlock contacts adding resistance to loop D high
- Moisture in a low-voltage connector of the loop medium
- Loop wiring routed too close to switching high-voltage cables low
- Signal input of the evaluating controller faulty low
Symptoms
- Sudden loss of high-voltage power while driving or charging
- Fault appears after rain, washing or on rough roads
- Restart sometimes possible after switching off and on
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for U351A
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?