High Voltage System Interlock Circuit C Low
U3517 says the level read back on interlock loop C stays too low. Depending on the design, an opened plug in loop C, a wire chafed to ground or a failed source in the monitoring module all lead to it. In current-fed designs such as the Texas Instruments reference circuit, a short to ground draws extra supply current while an opened loop does not, which helps to separate the two. For loop A, GM uses a 5 V test voltage and a 30 % lower limit, which indicates the margins involved. Mercedes has technicians measure interlock loop resistance segment by segment on model line 243, a method that suits loop C just as well. No manufacturer publishes U3517 itself. Until the fault is cleared, the contactors remain open.
Possible causes
- Interlock wire of loop C chafed to ground at a module or the body high
- Connector in loop C unplugged, sensed as a low signal medium
- Broken interlock connector housing or terminal medium
- Source stage for loop C failed in the monitoring module low