U3516
High Voltage System Interlock Circuit C Performance
U3516 flags loop C as electrically present but untrustworthy: resistance, timing or pattern of the returned signal fall outside what the module accepts, often only for moments. As the U35xx series has no intermittent code for loops B and C, unlike P0A0E for loop A, short dropouts will probably be stored here. The interlock patent from CATL names contact impedance, supply ripple and static discharge as sources of false trips, and Mercedes' bulletin for model line 243 links its interlock codes to oxidised low-voltage pins, bent pins at HV components and twisted harness runs; it adds that the HV component itself is rarely to blame. No maker documents U3516. Drivers notice HV shutdowns that come and go, often after rough roads or rain.
Possible causes
- Loose or spread contact in a connector of loop C high
- Oxidised low-voltage interlock pins medium
- Twisted or strained harness section moving with the body medium
- Static discharge or interference on the interlock line low
Symptoms
- Sporadic loss of ready mode
- HV warning that appears and clears by itself
- Fault hard to reproduce in the workshop
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for U3516
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.