U3513
High Voltage System Interlock Circuit B Low
U3513 reports a signal on interlock loop B that stays below its lower limit while the loop is energised by the module. What that means depends on the circuit: where the module feeds a test voltage in and reads it back at the far end, an opened plug reads low just like a wire touching ground. GM's documented loop A gives a sense of scale: its low code sets when less than 30 % of its 5 V check voltage comes back in two 12.5 ms samples, Type A. Texas Instruments' reference design shows how a current-fed loop can tell both apart: a grounded wire makes the loop current vanish while the supply current rises, with an open loop both drop. No maker publishes U3513. The contactors stay open; check loop B for chafed wires and unplugged connectors.
Possible causes
- Interlock wire of loop B chafed through to ground high
- Plug or cover in loop B open, read as low by the sensing circuit medium
- Pushed-back interlock terminal without contact medium
- Interlock source in the monitoring module not delivering its signal low
Symptoms
- No ready mode, HV contactors stay open
- Hybrid or EV warning lamp, MIL depending on maker
- Charging not possible
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for U3513
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.