U301F
Control Module Wake-up Circuit B Low
U301F reports wake-up line B held below its valid level, most often by a short to ground. Since B is a second, independent wake path, the module can still be roused through line A or the network; what it loses is the wake source wired to B. With an edge-triggered input such as the WAKE pin of NXP's TJA1043, which only reacts to a level change that remains stable for a short filter time, a grounded line simply never delivers that change. Its threshold sits only a few volts under battery voltage, so a partly shorted or corroded wire can count as low as well. No manufacturer documents U301F publicly. Unlike U301E, the circuit is not open, so a resistance check to ground with both connectors unplugged is the quickest way to find the fault.
Possible causes
- Wake-up wire B chafed and touching ground high
- Moisture or corrosion pulling line B down medium
- Source on line B with its output stuck low low
Symptoms
- Function tied to wake source B unavailable
- No other complaint while the module is awake
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for U301F
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
See repair cost, labour time and components?