U301B
Control Module Wake-up Circuit A Low
U301B means wake-up line A sits below its expected level, typically because it touches ground or is pulled down by a faulty sender. What happens next depends on how the receiving chip works. NXP's CAN transceiver TJA1043, for example, wakes on a change of the WAKE pin in either direction once the new level has stayed stable for a short filter time, and its switching threshold lies a few volts below battery voltage (typically battery minus 2.5 V). A line clamped to ground therefore produces no further edge and acts like an unused pin, so the module stays asleep when it should start. A wire that only sags, for example through corrosion, can drop under the threshold too. No manufacturer documents U301B publicly; compared with U301A, look first for chafing against body metal.
Possible causes
- Wake-up wire chafed through and touching ground high
- Corrosion or moisture pulling the level down at a connector medium
- Sending module output stuck low medium
Symptoms
- Module stays asleep, function or charging unavailable
- Lost-communication codes in other modules
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for U301B
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.