U300E
Ignition Input On
U300E deals with an ignition input that should be live only in On, without Start. Such run-only feeds exist because many loads are shed while the starter turns; GM's 2012 truck wiring manual, for instance, keeps its retained accessory power relay energized in all modes but two, crank and off-awake. If a module sees this run-only line high in Off or Accessory, or low while the network reports run, it stores U300E. A brief drop during cranking is intended and must not be judged as a fault, so a module that flags the code right after every start points more to a timing or software issue than to wiring. No manufacturer documents U300E publicly. A real wiring fault usually leaves functions on that feed dead with the engine running, which helps to separate the two cases.
Possible causes
- Blown fuse or faulty run relay on the run-only feed medium
- Input wire open, shorted or backfed medium
- Module software misjudging the intended drop during cranking medium
- Worn run contact in the ignition switch low
Symptoms
- Functions on the run-only feed dead with the engine running
- Code logged right after each start with no other complaint
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for U300E
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.