U069D
Lost Communication With Exhaust Gas Temperature Sensor Bank 2 Sensor 4
Sensor 4 is normally the final measuring position in the bank 2 exhaust, often placed further down the aftertreatment where the controller judges how hot the gas leaves the filter or catalyst stages. U069D reports that this digital probe has gone silent on its data link. Code-level documentation from a maker is not public; CARB only demands that a coded digital input which stops talking gets a code of its own. Sensience builds such probes from a type N thermocouple and a control module that handles up to four probes on J1939 CAN or one or two on SENT, so one failed module can silence several positions at once. On bank 1 only GM's 25OBDG04A contains the matching code U069B, rated Type A. Wiring faults of an analog probe at this point use P2473 to P2477, while U069C is the third probe. Expect a lit MIL and regeneration being delayed.
Possible causes
- Probe lead melted or torn near the rear aftertreatment high
- Electronics unit of the probe dead medium
- Supply fuse or feed wire of the probe faulty low
Symptoms
- Check engine light
- Regeneration delayed or cancelled
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for U069D
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.