U069C
Lost Communication With Exhaust Gas Temperature Sensor Bank 2 Sensor 3
U069C refers to the third temperature probe in the bank 2 exhaust path, so it can only occur where each cylinder bank feeds its own aftertreatment line, as on some V engines. Such a probe is a digital unit that reports its reading as SENT or CAN frames; the code is stored when those frames stop or keep failing their checks. No manufacturer documents U069C publicly. GM's 2025 diesels have one bank and test only the bank 1 positions, declaring a probe lost after 19 bad samples within 25 and rating it Type A. Bentley's V8 bulletin 2065698/1 proves that digital bank 2 probes are in use, yet names only the first position (U0621). An analog probe at this spot reports through P2466 to P246A, and the fourth probe on bank 2 has U069D. The MIL and a postponed filter regeneration are the likely consequences.
Possible causes
- Sensor harness on the bank 2 exhaust side chafed or heat-damaged high
- Electronics box of the probe failed medium
- Probe has lost its supply or ground medium
- Connector corroded or not latched low
Symptoms
- Check engine light
- Filter regeneration on bank 2 postponed or blocked
- Probe shows no value in live data
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for U069C
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.