U067C
Lost Communication With Fan 3
Some engines need a third electric cooling fan, for instance for a charge-air or auxiliary radiator, and LIN lets each fan carry its own speed electronics. GM's 2025 diesel table 25OBDG04B uses U067C for cooling fan 3: the response frame CFM3_Rsp must be missing for at least 2,437.5 ms, the LIN channel enabled and battery voltage above 11 V; the code is Type B, so the MIL lights after two trips. While it is active GM suspends the fan 3 speed checks, P2CBB for running slower than modelled and P30F2/P30F3 for feedback out of range, the high limit being 4,000 rpm. On the engines of GM's 23OBDG07 and 24OBDG07 the same fan instead sets the GM-specific U112A on a third LIN line. Watch engine temperature under load.
Possible causes
- LIN wire to fan 3 chafed or open high
- High-current supply, fuse or ground of fan 3 faulty medium
- Fan 3 controller electronics failed medium
- Fan connector corroded by road spray low
Symptoms
- Check engine light after two trips
- High coolant or charge-air temperature at low speed or when towing
- Fan 3 silent or running constantly
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for U067C
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.