U066E
Lost Communication With Charge Air Cooler Temperature Sensor Bank 2
A bank 2 charge air temperature only exists on V or boxer engines that run one turbocharger and one intercooler per cylinder bank. There the controller can compare both sides, and a mismatch belongs to P007F, the bank 1/bank 2 correlation code. U066E is the digital-link failure for the bank 2 sensor: its frames are missing or unusable, so that comparison and any per-bank boost correction lose their input. None of the Ford or GM OBD summaries examined shows a bank 2 charge air sensor at all, let alone a digital one, so no manufacturer can be named; analog faults would be P00A0 to P00A4. CARB's (f)(7.2.4) undercooling monitor applies per cooler. The controller substitutes the bank 1 value or a model; the driver rarely notices more than the warning lamp.
Possible causes
- Wiring to the bank 2 charge air sensor damaged, often routed near the hot side high
- Connector at the bank 2 charge air pipe loose or oily medium
- Bank 2 sensor electronics failed medium
Symptoms
- Check engine light
- Possible additional bank correlation code (P007F)
- Mostly unchanged driving behaviour
Inspection / repair
- Difficulty: easy
- DIY: possible
What Pro shows you for U066E
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.