Lost Communication With Right Rear Temperature Actuator B
With four rear temperature actuators, A and B on each side, plus front units, a climate system may run many look-alike motors on LIN, where one master serves up to 15 slaves. Identical parts must be told apart, either by part variant or by position detection along a daisy chain, as the LIN article explains. That makes right rear actuator B prone to a specific trap: a new or swapped unit that was never assigned its address answers on the wrong identifier, and the master logs U0662 although the part works. No maker documents this code publicly. A genuine loss only affects the fine mixing on the right rear side; actuator A keeps basic control there. Chips such as NXP's MM908E626 show the usual three-wire hookup of supply, ground and LIN.
Possible causes
- Replacement or swapped actuator B without the correct LIN address medium
- Actuator B electronics failed medium
- Open supply, ground or LIN pin at actuator B low
Symptoms
- Right rear temperature imprecise or slow to settle
- Code appears right after an actuator was replaced
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for U0662
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
See repair cost, labour time and components?