U0642
Lost Communication With EVAP System Pressure Sensor/Switch Circuit B
A second EVAP pressure sensor, B, appears where one reading is not enough, for instance when tank and canister are separated by an isolation valve and each side needs its own value, as in sealed tanks of plug-in hybrids that see higher pressures. Which location is called B is up to the manufacturer. U0642 is the lost-communication code for this sensor when it reports digitally; its analog counterpart logs P24D5 to P24D9. No manufacturer documents U0642 publicly. Because CARB 1968.2 (e)(15.2.1)(B)(i) demands a separate code for a digital input that stops talking, the code exists independently of U0641. While B is silent, the controller cannot compare both sides or check the isolation valve, so the leak test is suspended and a MIL is to be expected.
Possible causes
- Signal, supply or ground line to sensor B open or chafed high
- Corroded or unplugged connector at sensor B medium
- Sensor B electronics failed medium
- Receiving controller input or software fault low
Symptoms
- MIL on
- EVAP monitor incomplete
- On sealed tanks possibly a delayed fuel door release
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for U0642
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.