U063E
Lost Communication With Exhaust Heat Exchanger Bypass Valve Actuator A
Exhaust heat recovery passes hot exhaust through a coolant heat exchanger after a cold start, so the engine and cabin warm up sooner; a flap later diverts the gas around it. When that flap's actuator is a LIN slave, losing it gives U063E. GM documents the check in its hybrid tables 16OBDG02 through 19OBDG02, run by the second hybrid powertrain control processor: with the controller on, Run/Crank active, LIN enabled for at least 2 s and battery voltage at least 10.2 V, 80 missed replies at 40 ms intervals (3.2 s) fail it as Type B, MIL after two trips. A stuck flap can slow warm-up or keep heating the coolant when it should not. Circuit and position faults of the flap are P237C to P237F and P2C22 to P2C25; actuator B is U066C.
Possible causes
- Actuator electronics damaged by heat near the exhaust high
- LIN or supply wiring under the vehicle damaged or corroded medium
- Water ingress or corrosion in the actuator connector medium
- Weak 12 V supply interrupting LIN communication low
Symptoms
- MIL after two drive cycles
- Slower engine and cabin warm-up in cold weather
- Engine runs longer on hybrids to reach operating temperature
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for U063E
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.