U063D
Lost Communication With Hybrid/EV Electronics Coolant Pump A
The first electric pump of the power electronics loop, A, circulates coolant through the inverter, DC/DC converter and similar parts. Pumps of this class, such as Bosch's PAD2, take their speed command via PWM or LIN and run their own diagnosis; with LIN the controller also expects regular status replies. U063D is set when pump A stops answering. No manufacturer documents U063D publicly. California's OBD II regulation covers the outputs of inverter cooling too, which makes a lit MIL likely on hybrids. If the pump is dead rather than just mute, P2C68 (stalled) or P0CEA (performance) tend to follow. Pumps B and C report the same fault as U02BA and U02C1. The electronics heat up and the system cuts power.
Possible causes
- Blown fuse or open supply/ground to electronics coolant pump A high
- LIN wire to the pump open, shorted or chafed medium
- Pump electronics failed, often after running dry or overheating medium
- Fault in the hybrid or thermal controller acting as bus master low
Symptoms
- Hybrid system warning and MIL
- Reduced electric drive power or engine kept running on hybrids
- Inverter or electronics overtemperature messages
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for U063D