U061C
Lost Communication With Reductant Temperature Sensor A
Reductant temperature sensor A tells the controller how warm the diesel exhaust fluid is. That value decides when tank and line heaters must run, when dosing may begin after a cold start, and the concentration reading relies on it, since it is calculated from how fast sound travels through the fluid. On digital units the temperature element shares a housing with the level or quality measurement; SSI's ultrasonic tank sensor, for example, sends temperature, level and concentration together over J1939. U061C is logged when frames that carry temperature A no longer arrive or fail their checks. No manufacturer publicly documents a threshold or delay for this code. The analog circuit faults of the sensor are P2042 to P2046. In winter, a missing temperature can hold off SCR dosing for longer, so NOx emissions rise.
Possible causes
- Connector of the combined DEF tank sensor corroded or loose high
- Damaged data, supply or ground wire to the sensor medium
- Sensor electronics failed, sometimes after freeze damage medium
Symptoms
- Check engine light
- DEF heater or SCR dosing starts late or not at all in cold weather
- DEF quality reading unavailable
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for U061C
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?