U061A
Lost Communication With Reductant Level Sensor B
Some SCR tanks carry more than one level measurement, for example a second sensing element, a second tank chamber or a separate sender; which point counts as B is the manufacturer's choice, and no public document assigns it. U061A is stored when the controller stops receiving usable digital frames from level sensor B while sensor A may still report normally. That pattern points to the wiring branch, connector or electronics of the second sensor rather than to the network as a whole. Supplier sensors such as SSI's ultrasonic DEF unit put level and temperature on a J1939 CAN link, so a dead sensor looks to the controller like any missing node. Circuit-type faults of the same sensor are P21A8 to P21AC. Expect a warning lamp and a DEF reading that no longer matches the tank.
Possible causes
- Open or chafed wire in the branch that feeds only level sensor B high
- Water or corrosion in the connector of sensor B medium
- Level sensor B electronics failed medium
Symptoms
- Check engine light or DEF system warning
- DEF level shown wrongly or not at all
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for U061A
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.