Network
generic / SAE
U0614
Lost Communication With Intake Air Temperature Sensor 2 Bank 2
The vehicle bus reports loss of communication with smart IAT sensor 2 on bank 2 (typically post-intercooler). Charge-air density correction reverts to a substitute value.
SystemNetwork
Typegeneric / SAE
GroupU0
Range / number6 / 14
Possible causes
- Bus wiring open or shorted high
- Module without power or ground medium
- Module failed medium
Symptoms
- Multiple warning lights may illuminate
- Affected modules may go into limp mode or shut down
- Specific functions inoperative depending on module
- Diagnostic tools may show communication faults
Inspection / repair
- Difficulty: easy
- DIY: possible
- Estimated cost: 60–400 €
- Estimated time: 0.5–1.5 h
- Component: iat sensor 2 bank 2
- Component: vehicle bus wiring
- MIL / check engine light
- emissions-relevant
- drive cycle required
Sources
References
sae:J2012