U0599
Invalid Data Received From DC/DC Converter Control Module A
On start-stop vehicles a DC/DC converter can hold the 12 V supply for sensitive electronics while the starter pulls the voltage down; on hybrids it feeds the 12 V network from the high-voltage battery. GM's 2025 engine tables check the converter's output voltage and crank-control messages for alive counter, protection value and checksum errors and set U0599, Type B, after 8 failures in 18 samples with at least 11 V for 5 s. GM bulletin 20-NA-191 for the 2020 Cadillac CT4 and CT5 with auto start/stop shows the code set falsely: the ECM miscalculated the protection value during cranking without boost, disabled start-stop on the first failure and lit the MIL on the second; an ECM reprogram fixed it. FCA lists U0599 for the 2019 Cherokee V6 ESS; Ford's 2014 list has it without MIL.
Possible causes
- Engine controller software miscalculating the converter's protection value (GM 20-NA-191) high
- DC/DC converter A electronics faulty medium
- Weak 12 V battery causing deep voltage dips during cranking low
Symptoms
- Auto start/stop disabled
- Check engine light after repeated failures
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for U0599
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.