Network
generic / SAE
U0536
Invalid Data Received From Lateral Acceleration Sensor Module
A receiving module detected implausible data from the lateral acceleration sensor module. Lateral g values fail plausibility checks against steering and yaw rate and are rejected; ESC may be inhibited.
SystemNetwork
Typegeneric / SAE
GroupU0
Range / number5 / 36
Possible causes
- Module internal fault or sensor input drift high
- Software version mismatch after replacement medium
- Gateway module routing CAN messages incorrectly low
Symptoms
- Multiple warning lights may illuminate
- Affected modules may go into limp mode or shut down
- Specific functions inoperative depending on module
- Diagnostic tools may show communication faults
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
- Estimated cost: 200–1500 €
- Estimated time: 0.5–3 h
- Component: lateral acceleration sensor module
- MIL / check engine light
- drive cycle required
- limp mode possible
Sources
References
sae:J2012