U031B
Software Incompatibility With DC/DC Converter Control Module A
DC/DC converter module A moves energy between two voltage levels, in hybrids and mild hybrids typically from the high-voltage or 48 V battery to the 12 V system. U031B means another module does not accept the converter's software. Audi documents it for the 2022-2023 A3, S3 and RS 3 with 48 V mild hybrid: after a 48 V battery replacement, battery management 2 (J1120) may store U031B00, because the updated battery (5WA.915.107.B) runs a validation check of voltage converter A7 that converter software 5WA.959.663 does not answer. With exactly these two part numbers Audi says the code can be ignored (TSB 2068368/1). On other combinations a genuine mismatch can stop the 12 V supply from being charged, so watch for battery or charging warnings. U0298 means lost contact. The MIL normally stays off.
Possible causes
- 48 V/HV battery or its management replaced by a newer version the converter software does not support high
- DC/DC converter replaced without programming or coding medium
- Converter software behind the level of the other powertrain modules low
Symptoms
- Often no symptom, code found during service
- 12 V battery or charging warning possible
- Mild hybrid functions such as start-stop or recuperation limited
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for U031B
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.