U02AE
Lost Communication With Hybrid/EV Battery Coolant Pump
The battery coolant pump circulates coolant through the high-voltage pack. Electrically commutated pumps like Bosch's PAD2 carry their own electronics, take a speed request by PWM or LIN and report back. U02AE applies when such a pump is a bus node and stops answering the controller that runs battery thermal management. No manufacturer documents U02AE publicly. Pumps driven over a plain control line report P0C47 and its siblings instead: GM's 2019 hybrid table checks the HV battery pump line for under 200 mA or over 3 A while on, Type B. Under CARB 1968.2, every electronic input and output used to heat or cool the high-voltage battery must be monitored. Without the pump the pack warms faster, so charge and drive power may be limited. U0694 and U0695 name pumps A and B.
Possible causes
- Moisture or corrosion in the pump connector, pushed-out terminal high
- Pump electronics failed (seized rotor, internal fault) medium
- LIN/bus wire, supply fuse or ground of the pump interrupted medium
- Software fault in the battery or thermal management controller low
Symptoms
- Hybrid or battery warning, possibly with the MIL
- Reduced charging rate or electric drive power, especially when hot
- Battery temperature rises faster than usual
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for U02AE
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 4 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.