Network
generic / SAE
U0213
Lost Communication with Mirror Control Module
The body bus has lost the exterior mirror module. Folding, heating, dimming or memory functions of the mirrors stop working.
SystemNetwork
Typegeneric / SAE
GroupU0
Range / number2 / 13
Possible causes
- LIN wire to mirror open high
- Gateway module routing CAN messages incorrectly low
- CAN terminating resistor (120 Ω) drifted out of spec low
Symptoms
- Multiple warning lights may illuminate
- Affected modules may go into limp mode or shut down
- Specific functions inoperative depending on module
- Diagnostic tools may show communication faults
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
- Estimated cost: 60–400 €
- Estimated time: 0.5–2 h
- Component: mirror module
- Component: lin wiring
Sources
References
sae:J2012