Lost Communication With Fuel Heater Control Module
A fuel heater warms diesel ahead of the filter so that paraffin wax, which separates out in the cold, cannot clog the element; ordinary diesel turns to gel at roughly −15 to −19 °C. Newer designs use a microcontroller: a patent describes a heater controller that sets power from outside air temperature in open loop or from fuel temperature in closed loop, and cuts out when battery voltage falls too low. Where such a unit reports to the engine controller over the network, U01B6 means it has stopped answering and the heater state is unknown. No manufacturer documents this code publicly, and whether a MIL follows depends on how the maker rates the heater for emissions. In frost, expect hard starting, power loss or stalling from a waxed filter; in mild weather often nothing is noticed.
Possible causes
- Corroded or loose connector at the filter housing heater high
- Heater module supply fuse or relay failed medium
- Fuel heater control electronics faulty low
Symptoms
- Hard starting or stalling in frost
- Power loss from a clogged fuel filter in cold weather
- Often no symptom in mild weather
Inspection / repair
- Difficulty: medium
- DIY: possible