U008D
Vehicle Communication Bus G (+) High
U008D is stored when the (+) wire of Vehicle Communication Bus G carries excessive voltage, from a short to battery or another supply. No manufacturer documents U008D publicly. On a high-speed CAN this concerns CAN-High, and traffic often continues: NXP lists the fault among those that stay hidden unless a transceiver with bus diagnosis catches it, and onsemi saw frames still pass. The repair needs a second look, though. Texas Instruments warns that a bus wire in contact with a 24 V line drives the transceiver's short-circuit current through the terminating resistor and can burn out a 1/4 W part. After removing the short, measure the resistance between CAN-High and CAN-Low again; about 120 instead of 60 ohms means one terminator, often inside a module, has been damaged.
Possible causes
- (+) wire of Bus G touching a battery or 24 V feed high
- Water in a connector linking the bus to a supply pin medium
- Terminating resistor damaged by an earlier short low
Symptoms
- Often no symptom, code found during a scan
- Sporadic dropouts on Bus G after a wiring fault
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for U008D
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
See repair cost, labour time and components?