U0054
Vehicle Communication Bus C (-) Shorted to Bus C (+)
U0054 describes a short between the two wires of Vehicle Communication Bus C. Deutz uses it in main and secondary EMR L1 engine controllers as a short circuit on CAN 4, the same channel whose open circuit is U0048. On a high-speed CAN the bridged pair carries no differential voltage, so no dominant bit can form; onsemi measured the node's draw falling to about 47 mA, the lowest of all short types, because almost no transmission takes place. NXP's TJA1041 note adds that bus diagnosis in the transceiver cannot recognise this case. On fault-tolerant low-speed hardware like NXP's TJA1055, the bridged pair first looks like an endless dominant state; after 0.3 to 1.6 ms the chip disables CAN-Low and continues on one wire. Resistance across the pair close to zero, measured without battery, confirms it.
Possible causes
- Harness crushed so that both Bus C wires touch high
- Water in a splice or connector bridging the pair medium
- Damaged module input shorting its two bus pins low
Symptoms
- All modules on Bus C unreachable (high-speed type)
- Engine controller reports CAN fault, connected machine functions fail (Deutz)
Inspection / repair
- Difficulty: hard
- DIY: shop recommended