P341B
Deactivation/Intake Valve Control Circuit Performance Bank 2
With P341B the controller judges that intake deactivation on bank 2 is not doing its job even though no circuit fault is present: cylinders keep breathing when they should be sealed, or stay sealed after reactivation. No manufacturer documents this code publicly. One way to catch it is described in a Delphi patent: pressure pulses in the intake are timed against crank angle, and a missing or extra pulse shows which cylinder misbehaves. In practice, makers use their own codes instead, such as GM's P3498 series per cylinder or Honda's bank code P3497. CARB requires a functional check of such outputs. Electrical faults on the same bank are P340B; bank 1 is P341A. Oil level and quality are the first things to check.
Possible causes
- Oil level too low or oil past its service life high
- Lifter or rocker on bank 2 stuck in one switching state medium
- Control valve on bank 2 sticking or leaking past its seal medium
Symptoms
- Check engine lamp on
- Rough running, mostly at light load
- Misfire codes on bank 2
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for P341B
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.