Powertrain
generic / SAE
P2E9C
Charge Port Door B Position Sensor Circuit Intermittent/Erratic
The charge port door B position sensor reports a circuit intermittent/erratic condition. Door state cannot be verified reliably.
SystemPowertrain
Typegeneric / SAE
GroupP2
Range / numberE / 9C
Possible causes
- Position sensor failed high
- Wiring fault medium
- Connector with intermittent contact under vibration low
Symptoms
- Charge status indicator shows fault
- Charging may not start or interrupts
- Slower-than-expected charge rate
Inspection / repair
- Difficulty: easy
- DIY: possible
- Estimated cost: 80–400 €
- Estimated time: 0.3–2 h
- Component: charge port door b position sensor
- Component: wiring harness
- Component: bms
- MIL / check engine light
Sources
References
sae:J2012