P2E8F
Battery Charger B Charge Sequence Signal 2 Circuit Low
P2E8F reports the second CHAdeMO sequence line pulled low at a time it should be released. Because the station uses d2 to connect this line to ground as the very last step before the vehicle closes its contactors, and opens d2 first when the session ends, a line already at ground early, or still at ground once d2 is open, contradicts the sequence. A ground short in the inlet or harness, a station switch d2 that sticks closed, or a faulty input stage can be the cause. The vehicle then cannot be sure its contactor release is controlled by the station and normally refuses or aborts DC charging. No manufacturer documents P2E8F publicly; Siemens' CHAdeMO library for charging stations shows the station side, with relays d1 and d2 rated for 2 A. The high counterpart is P2E8E.
Possible causes
- Sequence signal 2 line shorted to ground high
- Fast charger switch d2 stuck closed medium
- Water or dirt in the DC inlet medium
- Faulty input stage in the evaluating control unit low
Symptoms
- DC fast charging refused right after plugging in
- Session ends with an error instead of a normal stop
- AC charging unaffected
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P2E8F
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.