P2E86
Battery Charger B Input Voltage Sensor Circuit High
P2E86 flags an input voltage signal of charger B above the highest value the measurement can plausibly produce. Home sockets and AC stations stay far below that, so the fault normally lies in the sensing path or its signal line, rarely in the grid. No manufacturer documents P2E86 publicly. The charger A versions give the scale: GM's 2011 Volt treats an AC peak above 422 V for 160 of 200 ms as sensor high (Type A, MIL), and Mitsubishi's Outlander PHEV sets P0D40 when the sensor output passes 3.161 V, equal to more than 492 V, for 0.5 s, then halts charging and names the charger/DC-DC unit as the part to replace. CARB wants hybrid monitoring plans to cover charging system performance. Too low is P2E85, plausibility P2E84. AC charging usually stays blocked.
Possible causes
- Voltage sensing circuit inside charger B faulty high
- Sensor signal line shorted to a supply voltage medium
- Lost reference ground of the measurement low
Symptoms
- AC charging refused or ended immediately
- Charging system warning in the cluster
- Fault returns at once after clearing, even on a known good charger
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for P2E86
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.