P2E72
Hybrid/EV Battery Pack B Cell Thickness Sensor Circuit Low
P2E72 means the pack B thickness sensor reports a signal below its valid floor. On a bridge-type strain gauge, the output is a small fraction of the excitation voltage that grows with strain, so losing that excitation or shorting a bridge leg to ground pulls the reading towards zero. Capacitive designs, such as a patented pressure-sensitive QTC sensor coated with indium tin oxide, depend on a measuring module that can fail the same way. LG's piezo elements in the cell gaps only output voltage under pressure, so a short across them hides real expansion. No manufacturer documents P2E72 publicly. CARB demands separate codes for low and high faults; the high side of this circuit is P2E71, pack A's low code P2E6E.
Possible causes
- Signal line or sensor shorted to ground inside pack B high
- Sensor excitation or reference supply lost medium
- Fault in the measuring circuit of the battery monitoring module low
Symptoms
- Hybrid or EV warning light
- Power or charging may be reduced as a precaution
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P2E72
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.